Uniform UI edge/enclosure lighting with low‑glare diffusers. Standardized harnesses speed assembly and service.
Total meters ≈ UI edge length × light lines per unit × no. of units.
Driver sizing = (W/m × total meters) × 1.25 headroom. Plan harnessing for quick module swaps.

Total meters ≈ UI edge length × light lines per unit × no. of units. Driver sizing ≈ (W/m × total meters) × 1.25 headroom.
| Voltage | W/m | lm/m | CRI | CCT | Cutting | Width | IP | Notes | Downloads |
|---|---|---|---|---|---|---|---|---|---|
| 24V | 8–10 | ~700–1000 | ≥90 | 4000–5000K | 50 mm | 8/10 mm | IP20/54 | Edge/UI lighting | Spectrum Report |
| 24V | 6–8 | ~500–800 | ≥90 | Neutral white | 50 mm | 8 mm | IP20 | Internal utility light | Datasheet |
Keep glare low on UI; plan EMI/EMC with kiosk electronics.
Download: Example spectrum report
Coverage depends on actual certified models and materials. Contact us for the certificate list per model.


IP20 is typical; higher IP for outdoor kiosks.
Use shielded routing and observe clearances.
Modular bars and labeled harness enable fast swaps.